Appendices
Appendix VHX: Version History
Scope: This appendix is the manuscript's version-history record. The main text states the current content of each result; this appendix records how that content reached its present form: the public releases, the registration and lifecycle records of the permanent registers, withdrawn and retired results, and prior values. The repository file
CHANGELOG.mdholds the same history release by release. Concept DOI (all versions): 10.5281/zenodo.20647445.
VHX.1 Public Releases
| Version | Date | Summary |
|---|---|---|
| v1.0.0 | 2026-06-11 | First public release. Withdrawn. |
| v1.0.1 | 2026-06-11 | Patch release. Withdrawn. |
| v1.1.0 | 2026-06-12 | Bibliography integrity pass over all 366 references; one lattice-Planck convention () across all volumes; tier labels aligned with their stated premises; cross-reference repairs; unified citation metadata. |
| v1.2.0 | 2026-06-13 | Engine documentation and tier-label hygiene. No scientific claim or numerical result was modified. |
| v1.2.1 | 2026-06-17 | The icosahedral selection result is stated at its proven scope; the "zero free parameters" phrasing is replaced by five postulates plus three anchors; the / relation is corrected. No numerical result changed. |
| v1.3.0 | 2026-10-26 | Withdrawals and corrections listed in §VHX.2–§VHX.4; Tier 0 (first-person datum); Level II open (Tier 3) for every substrate; parameter accounting of 11 declared core inputs and 24 numbered Ledger inputs, replacing "~16–19"; the preregistered constant control test and the Tier 4 evidential relabel of the φ-formula matches; the gauge-running check from the H-EW boundary recorded as FAILED; engine closure count 7 confirmed, 31 open, 12 conditional, 12 tension (62 protocols). |
| v1.4.0 | 2026-10-28 | Consolidation release that also withdraws claims and changes the parameter accounting. The version history is consolidated in this appendix and the main text states current content in the present tense; that restatement changes no number, tier label, verdict or claim. Corrections of printed values, tier labels and status wording are listed in §VHX.5; none of them changes a registered verdict or falsification rule. The internal-coherence changes, which withdraw claims, re-tier rows, and add or retire declared Ledger inputs, are listed in §VHX.6; with them the parameter accounting is 7 declared core inputs (5 structural postulates plus 2 continuous anchors, A1 and A3) and 32 numbered Ledger inputs (31 if C5 is treated as open), replacing 11 and 24 (23). Four pre-registered derivation tests return negative verdicts (§VHX.8), among them the O.47 dilution test, under which frozen phason strain cannot by itself be pressureless dark matter, and the horizon-entropy test, under which the declared action does not support the one-nat entropy density of the Newton- chain; Open Problems O.49 and O.50 are registered. The Protocol C stress gate (P.3) is suspended pending re-registration because its calibration rests on an overstated Bullet-shock pressure (§VHX.2). Two registered decision rules are restated in one form each (the Protocol C morphology rule (c) and the P.4 definition of definitive precision), Protocol C rule (a) becomes a one-sided 95% upper-limit rule at the same 94 Ms exposure, the P.1d band is the LOCKED 50 ppm, the Trp21 solvent-accessibility bound narrows the sensitivity band to , the 26 Ms morphology-power claim is withdrawn, and the named calibrated-handle subset grows from six to seven with the muon's (§VHX.6). The engine closure breakdown gains a fail category for registered failures: 7 confirmed, 30 open, 12 conditional, 8 tension, 5 fail (62 protocols), replacing 7 confirmed, 31 open, 12 conditional, 12 tension. |
Each public release is a citable snapshot under the concept DOI above. The release-by-release detail is in CHANGELOG.md.
VHX.2 Registration and Lifecycle Records
The machine registry GCT_Physics_Engine/falsifiability_registry.json and the App ORQ summary table are append-only: identifiers are never reused, renumbered or removed, and the Closed In field of a CLOSED or RETIRED row is permanent.
| ID | Record | Version |
|---|---|---|
| P.1b | The 55 ppm hard-FAIL edge of the tau tri-state gate (0–50 ppm PASS, >50–55 ppm AT-GATE TENSION, ≥55 ppm FAIL) is registered. Whether the edge predates knowledge of the ~50 ppm residual is not documented. | v1.2.0 |
| P.24 | The top-quark rule ( outside PDG ±5σ of the geometric prediction) and its comparator are registered. | v1.2.0 |
| O.20, O.22, O.31 | Closed. Up to v1.3.0 the closure field of these rows carried internal iteration numbers; v1.3.0 records their first public closure version, v1.0.0. | v1.0.0 |
| P.7c | Peak angular-correlation deviation , with a 5% SKA-PTA gate: withdrawn in v1.3.0 (orientation, physical transfer and observable normalization are not derived). Lifecycle: RETIRED; not empirically falsified. | v1.3.0 |
| P.7d | Linear coefficient , with a 5% SKA-PTA or combined-PTA null gate: withdrawn in v1.3.0 for the same reason. Lifecycle: RETIRED; not empirically falsified. | v1.3.0 |
| P.7e | Squared ratio , with a factor-two or SKA-PTA null gate: withdrawn in v1.3.0 for the same reason. Lifecycle: RETIRED; not empirically falsified. | v1.3.0 |
| P.3 | The Protocol C stress aperture keV cm (Perseus-core / Bullet-shock bracket) was registered in v1.0.0 (ID P.3). Its Bullet input, 4.0 keV cm from a 3–5 keV cm range, is overstated by a factor of roughly 20–90 (primary bow-shock analyses: – keV cm; – keV cm in electron pressure); with the corrected input the same recipe gives – keV cm, at which the relaxed Perseus inner core lies above the cut, so the threshold no longer separates cool cores from shocks. The registered value, rule and lifecycle (ACTIVE) are unchanged; the stress gate is suspended pending a dated re-registration, and the P.3 cluster-branch conditions are not executable until then (V3 Ch11 §11.1.4; V3 Ch15 §15.1.3). | v1.4.0 |
The engine's expected outcomes (GCT_Physics_Engine/config/expected_outcomes.json) were re-registered in v1.3.0 for these protocols:
protocol_absolute_scale.py(P.16): gates on the inherited 2001 ppm rule from P.1c and reports the 2273.725 ppm miss; the earlier undeclared 5000 ppm protocol tolerance and its "confirmed" closure were withdrawn.protocol_exponent_derivation.py(P.1c): the C3 threshold was corrected from an undeclared 1100 ppm to the LOCKED 1000 ppm rule; the 1006 ppm residual is a FAIL of that rule.protocol_quark_mismatch.py(P.23, P.24): top and bottom are scored against their registered PDG ±5σ rule (FAIL at 5.18σ and 6.90σ); the earlier 1% and 2% windows were not registered rules. The charm gate was set to the registered P.22 band (±3%), replacing an unregistered 5% tolerance.protocol_mixing_geometry.py: after the θ₂₃ comparator was corrected to NuFIT 6.0, θ₂₃ is no longer a tension (it was previously recorded asTENSION_GT_4SIGMA); the registered tension is carried by CKM (3.60σ), and the closure class is unchanged.
VHX.3 Constant Control Test
The preregistered constant control test (App PSC §PSC.9.6; frozen data, bundle hashes and verdicts in verification/constant_control_test/) was frozen three times:
| Version | Frozen | Validity check | Verdict |
|---|---|---|---|
| v1 | 2026-10-19 | INVALID: the scrambled-target negative control favoured φ (KS ); underpowered (power 0.06 and 0.10) | None issued |
| v2 | 2026-10-20 | INVALID: random-base -values not uniform on the real targets (KS ) | None issued |
| v3 | 2026-10-20 | Valid and powered | NEGATIVE-FRAGILE |
The Tier 4 evidential relabel of every φ-formula match (App PSC §PSC.9.6) was adopted in v1.3.0 on the basis of the v3 result. The global-significance figures of earlier editions (≈2.6σ, 3.1σ, 4.4σ, 5.4σ, the engine's 6.52σ and the cross-base ) were withdrawn in v1.3.0 and stay withdrawn.
VHX.4 Other Results Restated in v1.3.0
- Gauge-sector anchors. After the pre-registered gauge-running check from the H-EW boundary was recorded as FAILED (App GRF §GRF.4.3), v1.3.0 retired no input: A2 and A4–A6 (–) stayed in the count (11 declared core inputs; 24 numbered Ledger inputs). v1.3.0 left their retention open; v1.4.0 retires them (§VHX.6).
- Gravastar core density (V2 Ch10). The core-density programme was downgraded from Tier 3 to Tier 4 in v1.3.0: a single plateau cannot give a de Sitter core whose density scales as .
- Polaron Unity (App PUP). The disposition was corrected in v1.3.0. The former Hilbert-space non-factorizability proposition was withdrawn (an counterexample), the trace and factoriality questions were restated for and its central quotient, and what survives is an algebraic unity candidate.
- Projector normalization (App CXL §CXL.2, App DPS). Editions before v1.3.0 used one common scalar for both projection rows, a chart in which . From v1.3.0 the two rows carry separate normalizations, .
- Gram-ratio stiffness (V3 Ch14). The earlier "theorem" that the Gram eigenvalue ratio of the 6D→3D projection gives was withdrawn in v1.3.0: the ratio is a raw-frame normalization convention, not a physical stiffness.
- Phason stiffness ratio (V2 Ch03, Ch04; V3 Ch14; App DPS §DPS.3–§DPS.4b; App ORQ O.15, O.41). Editions before v1.3.0 derived from the cube of the Gram-determinant ratio, compared it with a – "phason-to-phonon stiffness ratio" attributed to i-AlPdMn measurements (a 100–1000× gap), and explained the gap by a Penrose-Toner "chemical-bonding floor" whose cited DFT source (DOI 10.1103/PhysRevB.88.144102) is a CaIrO study. v1.3.0 withdrew all three, and the energy scale GeV was replaced by the assignment GeV.
- Other withdrawn figures (v1.3.0). The top-quark value GeV, the one-octant "4.09σ" tension of , the bottom-quark window 4130–4230 MeV centred on the measurement, and the muon "theory floor" argument.
- Zeno-sector rates (V3 Ch13 §13.5; App ORQ O.16;
protocol_eta_zeno.py). With the demotion of the Rashba-phason coupling in v1.3.0, the 38.3 MHz single-spin coupling and every dependent and value became conditional external-rate scenarios rather than derivations. The numerical branches kept from earlier editions, including the zero-rate silicon control and the nonzero NV-centre band, are retained in that conditional sense.
VHX.5 Corrections in v1.4.0
These entries record values and labels printed in v1.3.0 that v1.4.0 corrects. None changes a registered verdict, a headline count or a falsification rule.
- N_coh scenario value (V1 Ch02, Ch11, Ch16, Ch17;
protocol_eta_zeno.py). v1.3.0 printed pre-overlap, a value computed with a 100 MHz drive, beside a post-overlap value () and an computed with the 112 MHz primary-branch drive. The engine (protocol_o16_n_coh_verification.py) evaluates both at 112 MHz: pre-overlap and post-overlap. The text now prints the engine pair with its drive frequency. - Gravastar tier (V2 Ch10, V2 Glossary, Master Glossary). v1.3.0 labelled the gravastar endpoint Tier 3 in V2 Ch10 and the Master Glossary and Tier 4 in the V2 Glossary. The endpoint rests on the Tier 4 core-density programme (§VHX.4), so it is labelled Tier 4 everywhere.
- CPL-fit gate (V3 Ch12 §12.1.3). One sentence of v1.3.0 called the state-level CPL-fit gate a live external-data tension while the same subsection, App PSC row 8 and V2 Ch14 §14.6.3 recorded it as falsified under its registered 3σ rule. The verdict is falsified; the single-channel template is the coordinate in sign-opposite tension.
- Polaron Unity closures (V1 Ch11;
protocol_o18_trefoil_meridian_trace.py). v1.3.0 listed the direct-product/operator-factor closure among the pending conditions of Proposition 11.12.A. App PUP refutes that step (Counterexample PUP.4.2.B), so it is no longer listed as pending. - Electron (P.5b). Labels printed before v1.3.0, "Cs 0.96σ agreement / Rb 3.94σ tension", were wrong and were withdrawn in v1.3.0; v1.3.0 described them as swapped, but the correction is not a swap (Cs-α gives 3.9σ, Rb-α gives 2.15σ). v1.3.0 printed the Rb-α gap as 2.1σ; v1.4.0 prints 2.2σ, the engine's rounding.
- Rounding of printed significances. PMNS : 1.6σ against NuFIT 6.0 with SK (v1.3.0 printed 1.5σ in App PSC, App FSM, App IVH and the registry; the computed value is 1.55σ). Bare Cabibbo formula: 16.3σ (v1.3.0 printed 16.2σ; computed 16.26σ).
- Logistic reference run (V2 Ch14). v1.3.0 quoted for the non-operative logistic reference run and tabulated , . The engine gives , and . The registered Class-2 band is unchanged.
- One-loop no-go bound (App GRF §GRF.4.3). v1.3.0 quoted the two-loop value in a bound labelled exact at one loop; the one-loop values are and –. The conclusion is unchanged.
- Dark-energy reference values (V2 Ch14; V3 Ch12 §12.4.1). v1.3.0 gave the broad logistic reference amplitude as in one place and in another; the engine value is , and the figure-caption factor to the envelope is about 219 (v1.3.0 printed 167). v1.3.0 stated that the Class-2 envelope had no normalized history; every Class-2 run shares , and O.17 is evaluated on the logistic history only. V3 Ch12 quoted a local- shift range that the engine does not produce; the engine values are / (kinematic) and / (linear fit).
- Protocol A-Prime chirality budget (V3 Ch13 §13.3.5). v1.3.0 gave two shot budgets for the same chirality-contrast gate, one at () and one at with the CISS dilution applied twice (). The single budget at the registered gate and 93% power is ( at ); the decision rule is unchanged.
- Floquet efficiency (App BEB §BEB.7; V3 Ch13 §13.4.6, §13.5.6–§13.5.7). v1.3.0 quoted as the on-resonance value at the bare MHz and used in App BEB, while the engine evaluates at 112 MHz with . is the value in the O.12-conditional renormalised branch; at the bare the same formula gives ; App BEB uses the engine's .
- O.23 OAM-breaking length (App ORQ O.23; V1 Ch17; V3 Ch13;
protocol_o23_dfs_collective_dressing.py). v1.3.0 labelled the length in the endpoint and defect channels of O.23 "the α-helical pitch (5.4 nm)". The α-helix pitch is 5.4 Å, and it is not the quantity the formula needs: the channels need a microtubule-lattice length (the same protocol uses the 8 nm dimer spacing). The label is withdrawn and 5.4 nm is kept as a Tier 3 placeholder inside the lattice range, with a sensitivity table over 4–12 nm (monomer, dimer, 3-start helix pitch). The verdict SHORT_OF_TARGET_EVEN_WITH_COLLECTIVE_DRESSING holds at every lattice length; only a sub-lattice length below 2.2 nm would reach the 10 ms target. Substituting 5.4 Å would have reversed the verdict (best collective 162 ms) through a quantity that does not enter the formula; that substitution is not made. The post-hoc acetylation-ratio envelope is centred on the placeholder output (523) and contains the bare ratio only for lengths of about 3.7–7.5 nm. "α-helical microtubule lattice" is restated as "helical microtubule lattice" in the O.23 context. - O.23 thermal floor (App ORQ O.23). v1.3.0 printed and a best-case bare s while quoting engine ratios computed with ; the engine values are and a best-case bare ms, and the regime table matches the engine.
- Energy-budget Zeno time (
protocol_zeno_energy_budget.py). v1.3.0 computed the bare Misra–Sudarshan time with (3.15 ns) while the decoherence audit used the 10 ns recombination interval (2.81 ns); both use the 10 ns recombination interval. - Reproduction script (
reproduce_standard_model.py). v1.3.0's script used hand-copied bands looser than the registry and reported every banded row inside its band, and it scored the CODATA input against itself. The script reads its rules from the registry and reports P.1c, P.16, P.23 and P.24 as FAIL and P.1b as AT-GATE TENSION, as the registry records; the row is an input echo. - Smaller corrections. The Higgs-VEV engine output listed O.20 among open problems (O.20 is closed at the enumeration level). The claim registry labelled the tau coefficient's as a Tier 2 integer (it is Tier 3 as a channel number). The PyPhi output was labelled "Tier 2 mechanism" (it is a Tier 3 toy-TPM witness) and the Protocol D Monte Carlo output "Tier 2 mechanism" (Tier 4, operationally unfalsifiable). The App PSC §PSC.8 entry for the 3.55 keV line stated a eV confirmation regime and an isotope-decay mechanism, against Protocol C (V3 Ch15 §15.1.4, §15.2) and the lattice-fracture mechanism; it gave the biogenic fingerprint gate as Roman Year-5 where V2 Ch14 requires Year-10 / Stage-V precision. V2 Ch14 stated a Shapley orientation gate where the registered P.9 rule is . App BEB §BEB.9 called the s scenario bound "preregistered"; no decision rule is registered for it. The bibliography located Thoen et al. (2014), Findlay et al., Goldsmith (2006), Kelber et al. (2003), Block (1995) and Block (2011b) at passages that did not cite them, and annotated Weiskrantz (1986) with a V1 Ch16 location and a "Level IIA evidence" reading that the chapter does not contain. V3 Ch21's first subsection had no number (now §21.1.1).
- Further corrections. The tau note of the Prediction/Postdiction Firewall gave the channel averaging of the screening factor as a Tier 2 mechanism; it is the Tier 3 convention of V3 Ch08 §8.2.2, and the Tier 2 part is the first-order phason-drag channel. V3 Ch08 called "unique to " without the restriction to finite irreducible Coxeter groups. The V3 Preface described a single inflation by mapping the tiling onto an inflated copy of itself; on the primitive lattice the self-similarity step is and a single maps to (App QCT §QCT.3.2). App TAT gave the right-handed hypercharges as "Tier 2 physical embedding" for -sterile states, and the registry, App FSM and the independent verifier gave the underlying assignment as Tier 2; the label is Tier 2 mechanism / Tier 3 physical singlet assignment (V3 Ch04 Theorem 4.2). The registry, App PSC and App FSM gave the bottom-quark 5/4 coefficient as Tier 2 (P.23); its use as the coefficient is a Tier 3 handle. App BEB called the – band "off-resonant", although the bare-gap detuned value is ; the band is the near-resonant/sub-Ohmic sensitivity band. V3 Ch13 §13.4 stated that a Protocol A-Prime/D null together with s "jointly rejects" the registered branch; the registered rejection rule is the F1 three-conjunct null of §13.3.5. App ORQ O.14/O.14a called the trace-image gap labels -valued without restricting this to the 1D Fibonacci AF core. The V3 Glossary stated the Polaron entry "in strict accordance with Mereological Nihilism"; that position is a Tier 3 interpretive proposal (V1 Ch16 §16.2.7).
reproduce_standard_model.pyreported P.19 as INFO and P.13b in bare mode as PASS; P.19 is scored on its registered PDG MeV rule and P.13b in bare mode is reported OPEN_CONDITIONAL, as the registry states.
VHX.6 Internal-Coherence Changes in v1.4.0
Each entry records a withdrawn claim or a changed headline; the main text states the resulting content.
- Top-quark row (V3 Ch10 §10.2; V3 Ch05 §5.3.2). The row is no longer presented as a top mass from lattice geometry. It rests on the declared Tier 3 input at the crystallization scale (Parameter Ledger H5); the factor is the Standard-Model doublet normalization, numerically equal to the face diagonal. Withdrawn: the " root-lattice face diagonal" attribution (the adopted lattice is ), the two unit-cell dilation mechanisms ("a facet by its diagonal" in V3 Ch10, "a cell by its own volume" in V3 Ch05), and the Tier 2 mechanism label. The value 174.072 GeV and the FAIL of the written P.24 rule () are unchanged. The numbered Ledger count rises by one (H5).
- Exponent grammar and Postulate G (Axiom & Postulate Ledger §2; Parameter Ledger §0.2; V3 Ch10; App FTH §FTH.5). v1.3.0 applied the candidate space of FTH.5 "to leptons, neutrinos, and quarks" while Postulate G restricted mass exponents to , so two admissibility rules coexisted without a stated sector boundary. v1.4.0 fixes one grammar per sector: Postulate G (integer exponents) covers only the lepton-ladder inputs P2, P4, P5, and the hadron and mixing sector uses . Every exponent, step and additive term of that sector becomes a declared Tier 3 Ledger input: H1 (charm ), H2a and H2b (CKM , ; formerly the single row H2), H3a–H3c (PMNS bare angles, the term of , the exponent 4; formerly the single row H3), H4 (proton), H6 (up exponent 3), H7 (strange exponent 8), H8 (bottom step ) and H9 (down-quark edge weight and identification). No number changes. The numbered Ledger count rises from 25 to 32.
- Down/up ratio (V3 Ch17 §17.2.3). The Protocol E face-area derivation , withdrawn in v1.3.0 (the AKN face-area ratio is 1 and the was not derived), is no longer narrated in the main text; the single down/up ratio is (V3 Ch10 §10.4).
- Phason speed (V2 Ch06 §6.2.2–§6.2.3; App ULA §ULA.5–§ULA.6; App TPS §TPS.1; App SNE §SNE.4; App ORQ O.48(b); Parameter Ledger row ). v1.3.0 exported a lattice speed of light from the stiffness-map hypothesis P3b by assuming one common inertial normalization for the phonon and phason sectors; with it the phonon speed was , and the subluminality premise of Theorem SNE.1 was recorded as failing under P3b. The common-inertia assumption and the speed export are withdrawn: P3b is a stiffness map only, the speed ratio is undetermined, and the ordering of and is open (O.48(b)). Withdrawn with it: the "1/76 scale" (V2 Ch06 §6.2.3), the Parameter Ledger convention , the update time , the lattice-unit evaluation , the density-of-states ratio (App TPS §TPS.1) and the claim that has a "vastly larger" density of states (V2 Ch07 §7.2.1, now a Tier 3 premise), and the bare phonon speed "" in the gravitational-carrier discussion. The neutrino floor ( eV, App PRG P.4), which uses and no speed, and the scale assignment are unchanged. The engine diagnostic
protocol_continuum_validation.pykeeps its verdict and labels as the reference value of the unit-mass harmonic model. - Dark-matter stress threshold (V3 Ch11 §11.1.3–§11.1.4; V2 Ch13 §13.1.1; V3 Ch15; Parameter Ledger C6). v1.3.0 wrote the yield stress as , stated that " is inherited from the phason-stiffness hierarchy", and described the Draco stress gate as having "no continuous fit parameter". Those statements are withdrawn: the Planck-scale stiffness of P3b gives Pa, – times the cluster bracket. The threshold becomes a declared Tier 3 calibrated input (C6; bracket –– keV/cm³, Protocol C value keV/cm³, unchanged), and the modulus in it is the cluster-scale , calibrated through and independent of P3b. The Draco gating is calibrated, not predicted. The Parameter Ledger tier of the candidate is aligned with V3 Ch11 (Tier 3, conditional on two Tier 3 inputs). The numbered Ledger count rises from 32 to 33.
- Dark energy from frozen strain (V2 Ch14 §14.1–§14.1.1; Prediction/Postdiction Firewall rule 5; App ORQ O.47; App PRG/FSM P.6b; App TAT). v1.3.0 read the frozen phason vacuum as a constant-density component with [Tier 3], while V2 Ch11 used the same frozen strain as clustering dark matter that dilutes as . The frozen-strain reading of is withdrawn: frozen strain is the dark-matter sector only, and with is the imported ΛCDM input (Parameter Ledger C4). The Tier 2 identification of with the de Sitter area ratio (§14.1.5) is unchanged. O.47 keeps its number and is restated as the open dilution law of the frozen-strain dark-matter sector (formerly "Dark-Matter / Dark-Energy Split of the Frozen-Strain Sector", with its void/uniform-density spatial tension, which no longer arises). P.6b keeps its number; its "frozen-phason baseline mechanism fails" falsification clause is withdrawn with the mechanism, and the row registers only the operative phason mass scale.
- Accessibility of (V2 Ch14 §14.1.5; V1 Ch06 §6.4.1). v1.3.0 stated that the coordinates "are not locally accessible from within " when grounding the entanglement-entropy reading of , while other chapters place light (the phason branch) and dark-matter strain in . The inaccessibility statement is withdrawn; tracing over is a Tier 3 modelling assumption of the entropy construction and of the formal Selection step. The Tier 2 identification of with the de Sitter area ratio is unchanged.
- Strange-quark coefficient (V3 Ch10 §10.4; App TAT). v1.3.0 justified the 12 both as the 12 pentagonal faces of the dodecahedral cage and as the coordination number, each presented as the Tier 2 mechanism. The Tier 2 claim is restricted to the existence of a face-channel drag; the multiplicity 12 is a Tier 3 counting convention, with the two readings recorded as alternatives that do not derive it, as for the lepton count. The value and its O.43 status are unchanged.
- Gauge-flow inputs A2 and A4–A6 (Parameter Ledger §0.1, §0.5; App GRF; V3 Ch04 §4.3.3, §4.5; V3 Ch22 §22.8; App TPR TP-A). v1.3.0 counted A2 (–25, the MSSM unified coupling) and A4–A6 (the native-RGE normalisations , , ) as continuous anchors and left their retention open after the pre-registered gauge-running check was recorded as FAILED. v1.4.0 retires all four: A2 for its MSSM provenance and its contradiction with H-EW for any Standard-Model extension, and A4–A6 because they restate the Standard-Model one-loop coefficients. Gauge-coupling running uses the Standard-Model -functions as imported standard physics, and the native irrep-activation kernel becomes an abandoned branch (App GRF §GRF.7); its outputs (, ) are kept as the record of that branch, and the FAILED verdict of the pre-registered audit is unchanged. The strong-coupling falsification condition of V3 Ch04 §4.5.5 quoted the 55.9% gap of the abandoned kernel; it is stated against the measured , which was already its target. TP-A of App TPR no longer concerns an input. The core accounting falls from 5 postulates + 6 anchors (11 declared core inputs) to 5 postulates + 2 anchors (7), and the numbered Ledger count falls from 33 to 29.
- Cluster cores (V2 Ch13 §13.1.1–§13.1.5; V3 Ch11 §11.1.4; V3 Ch15 §15.1). v1.3.0 stated that rich clusters (–) exceed the yield stress, so that their cores are in the fractured, fluid phase, and used this to account for cluster missing mass, while Protocol C's registered pressure cut places relaxed cool cores (Perseus, A2029, A1795) below . The fractured-core account is withdrawn: the fractured branch applies only to cluster regions above , and the missing mass of below-cut cores is a declared open programme. Protocol C's registered aperture is unchanged; changing a registered aperture after the result would break its pre-registration.
- Three further declared inputs (Parameter Ledger §0.2 H10, §0.4 C7–C8; V3 Ch09 §9.4.3; V2 Ch14 §14.1.4, §14.6.3). Three choices that v1.3.0 used without a Ledger row are declared as Tier 3 inputs: the PMNS CP phase (H10), the condensate route of Theorem 14.1.4 (C7, not evaluated), and the frozen-phason channel of the five-channel dark-energy menu (C8, a menu assumption). No number or verdict changes. The numbered Ledger count rises from 29 to 32 (31 if C5 is counted as an open problem).
- Newton- postdiction (App ULA §ULA.8; V2 Ch09 §9.1.4–§9.1.5; Parameter Ledger row ; App PSC §PSC.2, §PSC.9.7; App FSM P.16; Global and V1 Abstracts). v1.3.0 obtained by assigning one nat of horizon entropy per (§ULA.8 Step 2). The pre-registered horizon-entropy test gives for the harmonic ground state of the declared action (FAIL, §VHX.8), and under its pre-registered rule Step 2 is withdrawn. The chain no longer gives a value of ; the 2274 ppm figure is kept as the record of the withdrawn chain, and stays as a declared lattice–Planck convention. Of the two pre-registered consequences, a declared calibrated input (a new Ledger row fixing the density at one nat) or the withdrawal of Step 2, v1.4.0 takes the withdrawal; the density is therefore neither derived nor calibrated, and the main text states "no value of is claimed", "Step 2 is not made" (status WITHDRAWN). Registry row P.16 is kept with its arithmetic and its inherited FAIL; no Ledger input is added or retired.
- Count scope and identifications outside the count (Parameter Ledger §0.1, §0.5; Global Abstract; README; V3 Ch07–Ch08; App PSC; App TCD). v1.3.0 stated that the bare gauge + lepton sector is determined by 5 postulates + 1 dimensional anchor; the statement covers only the bare lepton-ratio sub-sector, since the bare relation (handle 360), H-EW, Cabibbo-bare and the SU(3) candidate use inputs outside that count. The elementary ladder step (rather than ), the O.38 posit and the per-row Planck-mass convention are listed as Tier 3 identifications outside the numbered count, and the lepton ladder is labelled a Tier 2 mechanism conditional on the Tier 3 -step (no longer "Tier 2 geometric postulate"); the 32 (31) count is unchanged. App PSC described the non-reduced Planck mass as "forced by empirical closure" against a geometry said to prefer ; it is a Tier 3 scale assignment chosen because it makes the exponent an integer.
- Tier statements aligned with the operative chapters. The right-handed hypercharge premise "right-handed singlets are -sterile" (Tier 2, App PSC and Parameter Ledger) is withdrawn; the singlet assignment is Tier 3 (V3 Ch04 Theorem 4.2). The tau coefficient's channel averaging is the Tier 3 convention of V3 Ch08 §8.2.2, and the use of 5/4 as the bottom-quark coefficient is a Tier 3 handle. The "Growth Axiom" is the Tier 3 generation-ordering assignment (Axiom & Postulate Ledger §4; it was labelled Tier 2 mechanism in the Master Glossary). The uniqueness of holds among finite irreducible Coxeter groups (reducible groups such as also reach 107), and the K-theoretic gap-labelling framework is rigorous for the 1D Fibonacci AF core, with the 6D AKN lift open (O.14) and Connes–Moscovici conditional (v1.3.0 called the framework Tier 2 rigorous for the AKN algebra in App ORQ, App TAT and App TCD).
- Summary claims narrowed to the chapters. The V2 Abstract no longer states that the dimensionless lattice speed is obtained (P3b exports no speed). The Global Abstract, V1 Ch01 and the glossaries state that GCT derives a formal Quality-Space scaffold (the 27-DOF decomposition, Tier 2) whose phenomenal identification is Tier 3 (O.29), not "the Quality Space of consciousness". The Hard-Problem statement (V1 Abstract, V1 Ch16, glossaries) is scoped to the existence of Level-I presence; the subjective Level-II question is an open Tier 3 bridge.
- Static curvature in the acoustic metric (V2 Ch08 §8.1.2; V2 Glossary). v1.3.0 stated that matter defects modulate the local stiffness and density, so that static Newtonian gravity arises from speed gradients, under a section labelled Tier 2. In the declared action of App ULA §ULA.2 the bond term is quadratic with fixed stiffness and node mass, and has no gradient dependence, so the action gives no matter-dependent stiffness or characteristic wave speed; the static-curvature source is stated as a Tier 3 open proposal that needs a matter–stiffness coupling not present in the declared action.
- Muon second-order term and the tau truncation (V3 Ch08 §8.2.3, §8.5, §8.6.2; V3 and Global Abstracts; V3 Ch14, Ch22; Parameter Ledger §0.1, §2; App PSC; App USS). v1.3.0 called the existence of the single-loop correction channel behind a Tier 2 mechanism and called the tau's first-order formula its full formula. is a Tier 3 fit handle applied to the muon only, conditional on H-EW, and joins the named calibrated-handle subset, which grows from six to seven; the 32 numbered Ledger inputs are unchanged. The tau formula is truncated at first order by choice: the muon's construction applied to the tau would add to the bare value (residual , MeV), and no derived rule excludes it. The Koide value depends on the one-row application (uniform first-order truncation gives , ). No residual changes.
- Protocol C morphology rule (V3 Ch15 §15.2; V3 Ch11, Ch22; App PRG/FSM P.3; App PSC; registry P.3). v1.3.0 stated rule (c) in three forms (a result short of for the stress template falsifies; a smooth-template preference of falsifies; smooth tracking alone falsifies). One three-outcome rule, the one the verifier implements, replaces them: at the exposure Ms at which the frozen mask reaches for a Bulbul-level line, with , a smooth or template preferred by falsifies; a stress-gated improvement of over both is morphology-compatible; anything between, or , is morphology-underpowered. This rule is weaker than the first of the three v1.3.0 forms.
- 26 Ms morphology power (V3 Ch15 §15.2; App PRG P.3; registry
morphology_power_rule). v1.3.0 stated that the 26 Ms milestone is powered to for one morphology degree of freedom. That claim is withdrawn: a Bulbul-level line is expected there at , so –, and rule (c) reaches at – Ms. The 26 Ms stack is a linewidth/flux milestone. - Direction of the α residual (App ULA §ULA.7.1; App ORQ O.19; Global Abstract; V3 Ch07;
protocol_o19_phason_alpha_magnitude.py). v1.3.0 called the 41.5 ppm post-bilayer O.19 target an anti-screening target with template-direction compatibility. The bare 3443 ppm shift has the anti-screening template direction; the 41.5 ppm target has the ordinary screening direction. No number changes, and O.19 stays OPEN. - Bottom-quark coefficient tier (
protocol_quark_mismatch.py,gct_spectrum.py,verify_engine.py, claim registryC_BOTTOM_QUARK_COEFF). The engine of v1.3.0 labelled the 5/4 coefficient Tier 2 and asserted that label. is Tier 1 arithmetic and its selection as the coefficient is the Tier 3 handle of V3 Ch10 (O.43), as the text and App FSM P.23 state; the verifier checks the Tier 3 label in the protocol output and the registry. No value changes. - P.6b row (App PRG; App PSC). v1.3.0 typed P.6b as a Consistency Check and gave the status "Calibrated" with the value eV. The row is a Declared Input, its status is Not evaluated (O.1), and the value is the Tier 3 operative input eV.
- Radical-pair Hamiltonian variance and pair coherence (V3 Ch13 §13.4; App BEB; V1 Ch17; App ORQ O.23; decoherence and energy-budget protocols; claim registry). v1.3.0 used the 30 MHz rms of three FAD couplings as the Hamiltonian variance . The variance of the §BEB.12 coupling list is MHz, so ns (was 5.305 ns), the bare ns (was 2.8 ns), Hz (was Hz) and ps (was 2.81 ps); the 30 MHz figure is kept only as a separate placeholder singlet–triplet gap. v1.3.0 also called the recombination channel inverse-Zeno; with no bath spectral density supplied, no Zeno/inverse-Zeno regime is assigned (App BEB §BEB.10). v1.3.0 also treated the imported s as the pair's coherence time; the recombination channel bounds that at ns, so the ratio required for the 10 ms stress target is (was ).
- Colour counting (V1 Ch16 §16.4; App ORQ O.29; App GPE;
protocol_psychophysics_color_dim.py). v1.3.0 counted human colour by colour space (3-D) and avian colour by chromaticity (3-D). One convention is used: the ceiling counts chromaticity, with luminance on the intensity axis, so cone classes give at most an -D chromaticity; human chromaticity is 2-D and avian 3-D, both within the ceiling. The engine verdict labelCOMPATIBLE_O29_STODDARD_MODEL_COMPARISONis renamedCATEGORICAL_LABELS_NOT_PREFERRED; the result is unchanged and does not test dimensionality. O.29 stays PARTIAL. - P.4 definitive precision (App NSM §NSM.1; App PRG/FSM P.4; registry P.4; V3 Ch22). v1.3.0 used "at definitive precision" without defining it or naming a prior or confidence level. The definition is two qualifying CDM collaboration analyses with independent large-scale-structure data, each on its baseline likelihood and stated prior, each reporting a one-sided 95% bound beyond the edge; it applies to both edges. The predicted value and the TENSION status are unchanged: DESI DR2 + CMB is one qualifying leg, and the second is open.
- Rules outside the count (Parameter Ledger §0.1 items (iv)–(vi), §2 row ; App PSC tau row; V3 Ch08 §8.3.2; App ORQ O.26, O.26b). v1.3.0 called the tau combination rule a structural or load-bearing Tier 3 postulate while listing it neither in the postulate count nor among the identifications outside it; the inserted negative screening sign and the equal-weight normalization were also unlisted. The three are listed outside the count as Tier 3 rules (iv)–(vi), and the combination rule is called a Tier 3 combination rule at its mirrors. The 5 + 2 accounting, the 32/31 Ledger count and the seven-handle subset are unchanged.
- P.1d band (registry P.1d; App FSM, App PRG, App PSC). v1.3.0 published a 100 ppm band for the bilayer-corrected row while
config/falsification_thresholds.jsonlocks 50 ppm. The LOCKED 50 ppm band binds; the 41.5 ppm residual stays inside it (margin 8.5 ppm). With P.1 and P.1d in different bands, the App FSM monotonicity proof covers 4 rows in 2 comparable band groups. - Protocol C rule (a) (V3 Ch15 §15.2, §15.1.3; V3 Ch11; App PRG/FSM P.3; App PSC; registry P.3). v1.3.0 falsified the stress-gated branch on "no line detected" at the 94 Ms 3σ sensitivity, where a Bulbul-level line is expected at exactly 3σ, so a true line was wrongly rejected about half the time. Rule (a) is a one-sided 95% upper limit in Ms: , the rule applies when , false rejection 0.05, probability 0.91 of applying with no line present [Tier 3 Gaussian estimate]. The exposure is unchanged.
- Protocol C target cells (V3 Ch15 §15.1.3; App PRG P.3; registry P.3
frozen_target_cells). v1.3.0 listed the Bullet shock and the relic and merger shells as target cells unconditionally although its own corrected pressures put them below the cut. Every listed cell is a candidate admitted only through the cut, and the registered aperture is stated to be expected empty, so the cluster branch carries no verdict under it. - Bound-water fraction (App NSP §NSP.4; V1 Ch17 §17.1.2c; V3 Ch16 §16.3.2, §16.6; Parameter Ledger B3, §3; App ORQ O.21, O.33; App PRG P.37; registry P.13, P.37;
verify_fbound.py,protocol_isotope_experiment.py). v1.3.0 gave Trp21 first-shell lumen waters (central 6), an band and a stress-test edge. The Trp21 side chain has 9.4 Ų of solvent-accessible surface in PDB 1JFF chain B (protocol_o21_trp_sasa.py), so and no second lumen-hydrated Trp exists. The sensitivity band becomes , the Protocol D sensitivity effect becomes , and the branch and stress-test edge are removed. - CISS band (V3 Ch13 §13.2; App NSP §NSP.5.1, §NSP.5.3; App BEB §BEB.11; App ORQ O.12; V3 Notation). v1.3.0 described Naaman, Paltiel & Waldeck 2019 in two incompatible ways (10–60% overall with 5–20% for proteins; a DNA-weighted 10–60% cut) and gave a 5–15% protein band to two oligopeptide papers, one of which is a charge-transfer-rate study. One Tier 3 protein/peptide envelope is used, pinned to Mishra et al. 2013; Göhler et al. 2011 supplies the DNA edge, and NPW 2019 is cited as a review. and the engine thresholds are unchanged.
- O.29 falsifier (App ORQ O.29; V1 Ch16 §16.4). v1.3.0 routed a demonstrated chromaticity of four or more dimensions to a substrate-dependent extension path, although the higher-dimensional irreps already carry other modalities. The extension path is withdrawn: such a result falsifies the 3-D chromaticity ceiling and the Tier 3 vision↔ assignment.
- Correlate versus identity (V1 Ch16 §16.2.2, §16.2.3, §16.2.8). v1.3.0 called topological friction the correlate of qualia "not their identity" while later sections adopted a reference-fixing identification. One disposition is used: a Tier 3 reference-fixing identity between Quality-Space role and the structural content of qualia (Layer B), and no identity between extrinsic structure and the intrinsic presence of Axiom 1 (Layer A).
- Citation scope, signs, bands and closure bins (V3 Ch08 §8.1.4; V2 Ch06 §6.1.2; V1 Ch16 §16.2; V2 Ch14 §14.5–§14.6; V3 Ch12; V3 Ch13; App BEB; App ORQ O.23; App PSC; App PRG P.6, P.8). Relative to v1.3.0: Gordon's 2003 diagonal-coinvariant theorem is cited for Weyl groups only, not for ; the V2 Ch06 phason Lagrangian carries the Feynman-gauge Maxwell overall sign; the experiential reading of Level-I presence is a Tier 3 bridge, not part of Axiom 1; is an adopted evaluation redshift, not a computed sensitivity peak, and the band is a registered declaration, not the V7' run envelope; the exclusion of the stage-hierarchy amplitude comes from the V6r SFR-age convolution, not from the Class-2 allocation; §BEB.12 assigns no inverse-Zeno regime to the bare recombination channel; the O.23 collective values are the engine outputs at the manuscript's hyperfine variance MHz ( ms at 5 µm and ms at 50 µm, replacing the ms band and the ms open-system range); is stated with its convention; the P.8 budget is stated as not executable as specified; App PSC law-level residuals are not called state-level; and registered failures have their own fail bin in the engine closure breakdown (7 confirmed, 30 open, 12 conditional, 8 tension, 5 fail). The main text states the narrowed content.
- Tier labels, scales and stated scopes (V1 Abstract; V1 Ch02, Ch11 §11.12, Ch16 §16.2.8, Ch17 §17.1, §17.5; V2 Ch14 §14.1.5; V3 Ch05, Ch06 §6.5.2, Ch07, Ch08, Ch09 §9.6.2, Ch10, Ch13 §13.3.5; Epistemic Tier System; Parameter Ledger; Firewall; App BEB; App DPS; App IVH; App NSM; App ORQ O.14, O.23, O.28, O.32; App PSC; App PUP; App TAT; App TCD; App USS). Relative to v1.3.0: the lepton harmonic ladder is a Tier 3 ansatz with Tier 1 -power arithmetic, not a Tier 2 mechanism; the Higgs-VEV product is Tier 1 arithmetic on the Tier 3 cage input; the identification of the de Sitter area ratio with is Tier 3; the Mixed-Harmonic Area Law is a Tier 3 heuristic, the hadron rows are Tier 3 handles, and no Planck-scale rooting of the hadron chain is claimed; the identification of the electron exponent with is Tier 3 (the arithmetic is Tier 1); the Tier 1 definition states that Tier 2 mechanisms follow from the axioms together with the cut-and-project ansatz; the O.23 collective-dressing protocol uses the manuscript's hyperfine variance MHz instead of 50 MHz, so its long-acetylated value is ms, above 1 ms; the tau is not called a high-discriminating postdiction; the NSM joint matrix grades no cell as support for both templates and no result as an exclusion of the dark-energy template; the PyPhi values are of standalone small networks, not subsystems of the icosahedral network; O.32's status covers a non-constraining sign realisation only; Strawson is recorded as an opponent on the subject thesis; an undefined protocol label and falsification route for the Seeley–DeWitt Higgs computation, a phantom co-localization requirement, a mis-classified microtubule drug, an unsourced chiral-cap reproducibility figure and a mis-pointed tier label are removed; Proposition 11.12.A / PUP.1 part (ii) is a scope statement. The main text states the narrowed content.
VHX.7 Former Names and Labels
In v1.4.0 the main text uses only the current name of each result. The names below appear in v1.3.0 and earlier editions.
| Current name or label | Former name or label | Location |
|---|---|---|
| Euclidean Stability Ansatz (Theorem 1.1) | "Euclidean Necessity" | V2 Ch01; Master Glossary |
| The polaron length scale [Tier 1 arithmetic; identification Tier 3] | labelled a theorem | V2 Ch03 |
| External Protected-Subspace Material Scenario | "Historical Protected-Subspace Material Scenario"; "Zeno Drive Shielding Constraint" | Prediction/Postdiction Firewall, item 4 |
| Spin–Phason Dimensional Firewall | "Biological Phason Freezing" | Prediction/Postdiction Firewall, item 6 |
| Protected-subspace / material-proxy programme | Zeno "Thermodynamic Feasibility Constraint" | Global Abstract |
| Conditional knot argument for three dimensions | "Knot-Theoretic Bound" | App TAT; App TCD |
| THz / isotope material-proxy programmes | "Terahertz signature of the Zeno Drive" | V3 Abstract |
| Bare fine-structure relation | "geometric impedance of the Rhombic Triacontahedron" | V3 Ch07 |
| Missing-leg control | "Turing Null" (a categorical verdict, withdrawn) | V3 Glossary; V1 Ch16–Ch17 |
| §PUP.6.3a Non-derivational surrogate | "Superseded surrogate" | App PUP |
| §BRC.5 Diagnosis of the Thermodynamic Argument | "Diagnosis of the Earlier Thermodynamic Argument" | App BRC |
| P.8 crossover comparison (declared open programme) | "Former Prediction P.8 crossover comparison" | App BEB |
| Hypothesis H-ICO (Platonic/icosahedral-package premise) | "Hypothesis H1" (collided with Parameter Ledger row H1) | App USS and its cross-references |
| Hypothesis H-KNOT (knot-theoretic premise) | "Hypothesis H2" (collided with Parameter Ledger row H2) | App USS; App FTH |
| Protocol C alternative hypothesis | "H1" (plain label) | V3 Ch15 |
| Generation-ordering assignment [Tier 3] | "Growth Axiom" | V3 Ch09; V3 Glossary; App PSC; Master Glossary; Master Index |
| Hierarchical distance : deepest shared cylinder | "first common branch node" | V1 Glossary; App TAS §TAS.4 |
| V1 §17.5 Conditions for a Future GCT–IIT Divergence | "GCT–IIT Divergence Predictions" | V1 Ch17 |
| V2 §14.7 Proposed Connection to Consciousness | "Historical Connection to Consciousness" | V2 Ch14 |
| App ULA §ULA.7.1 Phason Anti-Screening: a Tier 3 Candidate Sign Convention | "Topological Origin of Phason Anti-Screening" | App ULA |
| Protocol D substantive closure paths D1–D3 | a second list also lettered C1–C3 | V3 Ch16 §16.3.4 |
| Bulk-water scale | (also used for the 10 µs radical-pair baseline) | App BEB §BEB.2 |
Engine parameter external_rate_scale | legacy_external_rate_scale | protocol_eta_zeno.py and its results JSON |
Engine output key sign_labels_note | legacy_sign_labels_note | protocol_chirality_audit.py |
Engine output key reaches_comparison_target_10ms | reaches_selection_target_10ms | protocol_zeno_energy_budget.py, verify_engine.py |
| External bias scenario (; Parameter Ledger: supplied bias-voltage input) | "Historical bias scenario"; "Historical bias-voltage input" | V3 Ch13 §13.1; Parameter Ledger B4; Master Index |
| Shielding-factor scenario | "Historical shielding-factor scenario" | V3 Ch13 §13.4 |
| Protocol A-Tertius objective | "Objective (historical)" | V3 Ch13 |
| Biological scenario ("geometric" mode) | "Historical biological scenario" | V3 Ch13 |
| V3 §22.1.2 THz Material-Emission Scenario | "Historical THz Material-Emission Scenario" | V3 Ch22; App ORQ (Protocol A list) |
| PTA peak-deviation amplitude; PTA linear-Legendre coefficient; PTA squared-power ratio (P.7c–e) | "Historical PTA …" | Registry; App FSM |
Two further records:
- Higgs-scale anchor. The calibration anchor was withdrawn in v1.3.0; no engine protocol produces a value for it (Parameter Ledger).
- Bound-water fraction (V1 Ch17 §17.1.2c, App NSP §NSP.4). Editions before v1.3.0 multiplied by an extra face factor and divided by the water of a whole 8 nm ring (13 dimers); removing both shifted every value by a factor 13/12.
VHX.8 Results Added in v1.4.0
- Koide/ derivation test (App PSC §PSC.9.7; V3 Ch08 §8.6.1). Pre-registration frozen 2026-10-21 (SHA-256
1b8f11bf…fd312); verdict NOT DERIVED. Path (a) of the §8.6.1 closure target is restated accordingly: representation theory alone does not fix the Koide ratio. - -exponent ladder test, rule (a) (App PSC §PSC.9.7; App USS §USS.5.4). Pre-registration frozen 2026-10-20 (SHA-256
8046b600…c42809); verdict NOT SUPPORTED; blind check 65/65. No input count changes. - O.47 dilution-law test (App ORQ O.47; App PSC §PSC.9.7; V2 Ch11, Ch13, Ch14; Global and V2 Abstracts). Pre-registration frozen 2026-10-28 (SHA-256
e3a78bd7…c7f3c2); verdict FAIL [Tier 2 conditional on the Tier 3 covariant reading]: frozen phason strain has and cannot by itself be pressureless dark matter. O.47 stays OPEN for the cosmological dark-matter component. No input count, registered verdict or closure figure changes. - Horizon entropy density of the Newton- chain (App ULA §ULA.8; V2 Ch09 §9.1.4–§9.1.5; App PSC §PSC.9.7; Parameter Ledger row ; App FSM P.16). Pre-registration frozen 2026-10-27 (SHA-256
b697fc87…023324; three dated amendments, each the conservative option, adopted before the full run); verdict FAIL: the harmonic ground state of the declared action gives (–), below the registered lower band 0.5. The one nat per of the chain is stated as an assignment, and the 2274 ppm figure as not supported by the declared action. Under the pre-registered consequence §ULA.8 Step 2 is withdrawn, so the chain no longer gives a value of and the 2274 ppm figure is kept only as a record (§VHX.6). No input count, registered verdict or closure figure changes.
The frozen records of the four tests are in verification/koide_a5_test/, verification/rule_a_e8_test/, verification/o47_dilution_test/ and verification/eta_entropy_density_test/.
VHX.9 Index of Withdrawn and Retired Statements
The main text states each item below in the present tense ("is not claimed", "is not used", "is not made"). This index records that earlier editions stated it. Items already described in §VHX.2–§VHX.8 (the "4.09σ" θ₂₃ tension, the 4130–4230 MeV bottom-quark window, the muon "theory floor" argument, the global-significance figures, Proposition PUP.1(ii), the Gram-ratio and Gram-cube stiffness routes, the "Turing Null" verdict) are not repeated.
| Statement (earlier editions) | Where the current statement is |
|---|---|
| The "Direct Incongruence Argument" label for the conceivability-gap objection, attributed to Chalmers 2010 Ch.10 | V1 Ch16 §16.2.8a |
| The RT acceptance-window solid-angle construction as the mechanism of , with (the RT faces subtend ) | V1 §13.2.1–§13.2.2; Parameter Ledger row |
| The single- phason-elasticity formula and the acoustic-metric routes (Routes 2/3) to , and the description of that expression as a secondary validation of | App DPS §DPS.7; V2 Ch08, Ch09 §9.1.5; V1 Ch13 |
| The WZW "hemisphere" step giving , and Theorem CCD.1 (tether-induced half-integer spin) | App CCD §CCD.4; V1 Ch15; App TAT, App TCD |
| A vertex-star count of 32 | App CXL |
| The tethered-ribbon framework, and the trefoil-to-Fibonacci substitution route as a derivation | App PUP |
| The substitution of the cage count into , and the tree-depth values derived from it | V1 Ch07 §7.4.3 |
| External-world rigidity, billions of active Selection Operators and an infinite energy requirement as consequences of the consensus protocol | V1 Ch11 |
| The argument that distant points are adjacent in the 6D parent space | V2 Ch03 |
| The inscribed-sphere / RT-volume motivation for , and the 144-node negative quadratic coefficient, GeV and | V3 Ch05 |
| A "10–20 MHz indole band" and a "6–11×" renormalization factor | V3 Ch13; App ORQ O.12 |
| A cavity enhancement of the thermal floor (with its W / W floors), the cavity-floor margin, and the / modulation rule | V3 Ch13 §13.3.2b; App ORQ O.10; App PRG / App FSM P.8b |
| The A-Tertius effect size, sample-size plan and LGI decision rule | V3 Ch13; App PRG / App FSM P.8c |
| The 50 kHz drive-window decision rule | V3 Ch13; App FSM P.44 |
| The "clear by a factor of ten" acceptance criterion | Prediction/Postdiction Firewall |
| A " ppm" exchange bound (a frequency unit applied to a time) | V3 Ch16 |
| The scale-separation decoupling argument with nm, and unsourced Ohmic / sub-Ohmic spin-bath labels | App BEB |
| "Ports" mechanism language and a face-count form that counts the same 12 faces twice | App NSP |
| A bound-water sensitivity ladder that divides a per-dimer count by the water of a 13-dimer ring | App NSP §NSP.4 |
| The 0.1° CMB TB+EB gate (with its gray zone and six-bin protocol), the 0.05 rad² FRB six-fold gate (with its gray zone), the PTA amplitude claims P.7c–e, the criterion and the RM amplitude/null subclaim | App PRG / App FSM P.7c–e, P.11, P.12, P.43, P.46 |
| The Planck 2018 0.12 eV bound as a gate, and the DESI 2024 bound as the registered comparator | App PSC; App FSM P.4; engine gct_constants.yaml |
| The PDG 2024 value as the D5 comparator | App GRF |
| A 2500% continuum tolerance, 1%/2% quark tolerances, a bound-water band and a susceptibility placeholder in the engine | engine sources and gct_constants.yaml |